ubuntukid
(usa Debian)
Enviado em 29/01/2018 - 11:48h
Mesmtest+86: Deu tudo certo, não apontou nenhum erro de memória.
#hdparm -v /dev/sda
/dev/sda:
multcount = 16 (on)
IO_support = 1 (32-bit)
readonly = 0 (off)
readahead = 256 (on)
geometry = 60801/255/63, sectors = 976773168, start = 0
# fdisk -l:
Disk /dev/sda: 465,8 GiB, 500107862016 bytes, 976773168 sectors
Units: sectors of 1 * 512 = 512 bytes
Sector size (logical/physical): 512 bytes / 4096 bytes
I/O size (minimum/optimal): 4096 bytes / 4096 bytes
Disklabel type: dos
Disk identifier: 0x6adbfb8b
Dispositivo Inicializar Start Fim Setores Size Id Tipo
/dev/sda1 * 2048 968587263 968585216 461,9G 83 Linux
/dev/sda2 968589310 976771071 8181762 3,9G 5 Estendida
/dev/sda5 968589312 976771071 8181760 3,9G 82 Linux swap / Solaris
Partition 2 does not start on physical sector boundary.
Li em alguns fóruns que é ok ignorar esse aviso de Partition 2 does not start on physical sector boundary e mesmo que eu quisesse resolver, não achei nenhum tópico que ensinasse como fazer.
# htop
https://imgur.com/menJSKu
# smartctl -a /dev/sda
smartctl 6.5 2016-01-24 r4214 [x86_64-linux-4.13.0-31-generic] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke,
www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Toshiba 2.5" HDD MK..75GSX
Device Model: TOSHIBA MK5075GSX
Serial Number: 52IBY6POF
LU WWN Device Id: 5 000039 40d285742
Firmware Version: GT001U
User Capacity: 500.107.862.016 bytes [500 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Mon Jan 29 11:43:02 2018 -02
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 120) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 194) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0
2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline - 0
3 Spin_Up_Time 0x0027 100 100 001 Pre-fail Always - 2792
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 174
5 Reallocated_Sector_Ct 0x0033 100 100 050 Pre-fail Always - 0
7 Seek_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0
8 Seek_Time_Performance 0x0005 100 100 050 Pre-fail Offline - 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 324
10 Spin_Retry_Count 0x0033 103 100 030 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 96
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 18
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 32
193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 245
194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 41 (Min/Max 16/48)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
220 Disk_Shift 0x0002 100 100 000 Old_age Always - 8296
222 Loaded_Hours 0x0032 100 100 000 Old_age Always - 199
223 Load_Retry_Count 0x0032 100 100 000 Old_age Always - 0
224 Load_Friction 0x0022 100 100 000 Old_age Always - 0
226 Load-in_Time 0x0026 100 100 000 Old_age Always - 299
240 Head_Flying_Hours 0x0001 100 100 001 Pre-fail Offline - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 296 -
# 2 Short offline Completed without error 00% 292 -
# 3 Short offline Completed without error 00% 107 -
# 4 Short offline Completed without error 00% 101 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
E agora, qual será o problema? O PC continua do mesmo jeito. Às vezes melhora, mas ainda assim não está 80% satisfatório